PVC CABLE--- CCC |
|
CONDUCTOR |
INSULATION |
JACKET |
No.of core |
sectional area(mm 2 ) |
Nom.Thick.(mm) |
Nom.Diam.(mm) |
Nom.Thick.(mm) |
Nom.Diam.(mm) |
2 |
0.5 |
0.5 |
1.95 |
0.6 |
5.2 |
0.5 |
1.95 |
3.255.20 |
0.75 |
2.15 |
5.6 |
0.75 |
2.15 |
3.605.75 |
3 |
0.5 |
1.95 |
5.6 |
0.75 |
2.15 |
5.9 |
|
CONDUCTOR |
INSULATION |
JACKET |
No.of core |
sectional area (mm 2 ) |
Nom.Thick. (mm) |
Nom.Diam.(mm) |
Nom.Thick. (mm) |
Nom.Diam.(mm) |
2 |
0.75 |
0.6 |
2.35 |
0.8 |
6.3 |
0.75 |
0.6 |
2.35 |
0.8 |
|
1.0 |
0.6 |
2.55 |
0.8 |
6.8 |
1.5 |
0.7 |
3.00 |
0.8 |
7.8 |
3 |
0.75 |
0.6 |
2.35 |
0.8 |
6.5 |
1.0 |
0.6 |
2.55 |
0.8 |
7.1 |
1.5 |
0.7 |
3.00 |
0.9 |
8.3 |
227 IEC 53(YZ)/57(YZW)-300/500V |
|
|
|
CONDUCTOR |
INSULATION |
JACKET |
WIRE EXRADIUS |
No.of core |
sectional area (mm 2 ) |
Nom.Thick. (mm) |
Nom.Diam.(mm) |
LTM DOME.(mm) |
LTM DOME.(mm) |
2 |
0.75 |
0.6 |
0.8 |
6.0 |
8.2 |
1.0 |
0.6 |
0.9 |
6.6 |
8.8 |
1.5 |
0.8 |
1.0 |
8.0 |
10.5 |
0.75 |
0.6 |
0.8 |
6.5 |
8.8 |
3 |
1.0 |
0.6 |
0.9 |
7.0 |
9.2 |
1.5 |
0.8 |
1.0 |
8.6 |
11.0 |
|
PVC POWER SUPPLY CORDS --- VDE |
H05RR-F/H05RN-F |
|
|
|
CONDUCTOR |
INSULATION |
JACKET |
WIRE EXRADIUS |
No.of core |
sectional area (mm2) |
Nom.Thick. (mm) |
Nom.Thick.(mm) |
LTM DOME(mm) |
LTM DOME(mm) |
2 |
0.75 |
0.6 |
0.8 |
6.0 |
8.2 |
1.0 |
0.6 |
0.9 |
6.6 |
8.8 |
1.5 |
0.8 |
1.0 |
8.0 |
10.5 |
2.5 |
0.9 |
1.1 |
9.5 |
12.5 |
3 |
0.75 |
0.6 |
0.9 |
6.5 |
8.8 |
1.0 |
0.6 |
0.9 |
7.0 |
9.2 |
1.5 |
0.8 |
1.0 |
8.6 |
11.0 |
2.5 |
0.9 |
1.1 |
10.0 |
13.0 |
4 |
0.75 |
0.6 |
0.9 |
7.1 |
9.6 |
1.0 |
0.6 |
0.9 |
7.6 |
10.0 |
1.5 |
0.8 |
1.1 |
9.6 |
12.5 |
2.5 |
0.9 |
1.2 |
11.0 |
14.0 |
5 |
0.75 |
0.6 |
1.0 |
8.0 |
11.0 |
1.0 |
0.6 |
1.0 |
8.5 |
11.5 |
1.5 |
0.8 |
1.0 |
10.5 |
13.5 |
2.5 |
0.9 |
1.3 |
12.5 |
15.5 |
H07RN-F |
CONDUCTOR |
INSULATION |
JACKET |
WIRE EXRADIUS |
No.of core |
sectional area (mm2) |
Nom.Thick. (mm) |
Nom.Thick.(mm) |
LTM DOME(mm) |
LTM DOME(mm) |
2 |
1.0 |
0.8 |
1.3 |
8.0 |
10.5 |
1.5 |
0.8 |
1.5 |
9.0 |
11.5 |
2.5 |
0.9 |
1.7 |
10.5 |
13.5 |
3 |
1.0 |
0.8 |
1.4 |
8.6 |
11.5 |
1.5 |
0.8 |
1.6 |
11.5 |
12.5 |
2.5 |
0.9 |
1.8 |
0.8 |
14.5 |
4 |
1.0 |
0.8 |
1.5 |
9.6 |
12.5 |
1.5 |
0.8 |
1.7 |
10.5 |
13.5 |
2.5 |
0.9 |
1.9 |
12.5 |
15.5 |
5 |
1.0 |
0.8 |
1.6 |
10.5 |
13.5 |
1.5 |
0.8 |
1.8 |
11.5 |
15 |
2.5 |
0.9 |
2.0 |
13.5 |
17 |
|
PVC POWER SUPPLY CORDS --- UL/CSA |
SPT-1 |
|
|
|
CONDUCTOR
|
INSULATION |
JACKET |
AMP RATING |
AWG Size |
sectional area (mm2) |
Nom.Thick. (mm) |
Nom.Diam. (mm) |
Nom.Thick.
(mm) |
Nom.Diam.
(mm) |
18 |
0.82 |
- |
- |
0.76 |
2.705.35 |
10A |
18 |
0.82 |
0.76 |
2.0 |
0.76 |
2.708.30 |
10A |
SPT-2 |
18 |
0.82 |
- |
- |
1.14 |
3.506.95 |
10A |
16 |
1.31 |
- |
- |
1.14 |
3.757.55 |
13A |
18 |
0.82 |
0.38 |
2.15 |
1.14 |
3.609.50 |
10A |
16 |
1.31 |
0.38 |
2.40 |
1.14 |
4.0010.4 |
13A |
SVT |
|
|
|
CONDUCTOR |
INSULATION |
JACKET |
AMP RATING |
AWG Size |
sectional area (mm2) |
Nom.Thick. (mm) |
Nom.Diam.(mm) |
Nom.Thick. (mm) |
Nom.Diam.(mm) |
18 |
0.82 |
0.38 |
2.05 |
0.76 |
5.90 |
10A |
17 |
1.03 |
0.38 |
2.20 |
0.76 |
6.20 |
12A |
16 |
1.31 |
0.38 |
2.30 |
0.76 |
6.40 |
13A |
18 |
0.82 |
0.38 |
2.5 |
0.76 |
6.25 |
7A |
17 |
1.03 |
0.38 |
2.20 |
0.76 |
6.60 |
9A |
16 |
1.31 |
0.38 |
2.30 |
0.76 |
6.80 |
13A |
SJT/SJTW/SJTO/SJTOW |
|
|
|
CONDUCTOR |
INSULATION |
JACKET |
AMP RATING |
AWG Size |
sectional area (mm2) |
Nom.Thick. (mm) |
Nom.Diam.(mm) |
Nom.Thick. (mm) |
Nom.Diam.(mm) |
18 |
0.82 |
0.76 |
2.80 |
0.76 |
7.25 |
10A |
16 |
1.31 |
0.76 |
3.10 |
0.76 |
7.80 |
13A |
14 |
2.08 |
0.76 |
3.50 |
4.00 |
8.70 |
15A |
12 |
3.31 |
0.76 |
4.00 |
1.14 |
10.30 |
20A |
18 |
0.82 |
0.76 |
2.80 |
0.76 |
7.8 |
7A |
16 |
1.31 |
0.76 |
3.10 |
0.76 |
8.4 |
10A |
14 |
2.08 |
0.76 |
3.50 |
1.14 |
9.30 |
15A |
12 |
3.31 |
0.76 |
4.00 |
1.52 |
11.0 |
20A |
18 |
0.82 |
0.76 |
2.80 |
0.76 |
8.45 |
7A |
16 |
1.31 |
0.76 |
3.10 |
0.76 |
9.20 |
10A |
14 |
2.08 |
0.76 |
3.50 |
0.76 |
10.20 |
15A |
12 |
3.31 |
0.76 |
4.00 |
1.14 |
12.10 |
20A |
|
PVC POWER SUPPLY CORDS --- SAA |
250/250 FLAT FLEXIBLE CORDS |
|
SAA |
|
CONDUCTOR |
INSULATION |
JACKET |
No.of core |
sectional area (mm 2 ) |
Nom.Thick. (mm) |
Nom.Diam.(mm) |
Nom.Thick. (mm) |
Nom.Diam.(mm) |
2 |
0.5 |
0.8 |
- |
- |
3.05.7 |
0.75 |
0.8 |
- |
- |
3.36.3 |
250/440 FLAT FLEXIBLE CORDS |
2 |
0.5 |
0.6 |
- |
- |
4.26.3 |
0.75 |
0.6 |
- |
- |
|
250/440 ORDINARY DUTY FLEXIBLE CORDS |
CONDUCTOR |
INSULATION |
JACKET |
No.of core |
sectional area (mm 2 ) |
Nom.Thick. (mm) |
Nom.Diam.(mm) |
Nom.Thick. (mm) |
Nom.Diam.(mm) |
2 |
0.75 |
0.6 |
2.35 |
0.8 |
7.0 |
1.0 |
0.6 |
2.55 |
0.8 |
7.2 |
1.5 |
0.7 |
3.00 |
0.8 |
8.2 |
3 |
0.75 |
0.6 |
2.35 |
0.8 |
7.4 |
1.0 |
0.6 |
2.55 |
0.8 |
|
1.5 |
0.7 |
3.00 |
0.9 |
|
227 IEC 53(RVV)-300/500V |
|
SAA |
|
CONDUCTOR |
INSULATION |
|
No.of core |
sectional area (mm 2 ) |
Nom.Thick. (mm) |
Nom.Diam.(mm) |
Nom.Thick. (mm) |
Nom.Diam.(mm) |
2 |
0.75 |
0.8 |
2.55 |
1.3 |
8.8 |
1.0 |
0.8 |
2.75 |
1.3 |
9.0 |
1.5 |
0.8 |
3.20 |
1.5 |
10.1 |
3 |
0.75 |
0.8 |
2.55 |
1.4 |
9.5 |
1.0 |
0.8 |
2.75 |
1.4 |
|
1.5 |
0.8 |
3.20 |
1.6 |
10.8 |
4 |
0.75 |
0.8 |
2.55 |
1.5 |
10.5 |
1.0 |
0.8 |
2.75 |
1.5 |
10.7 |
1.5 |
0.8 |
3.20 |
1.7 |
11.8 |
|
|